160-022-100
This page provides complete and verified information for part number 160-022-100, NSN: 5925-01-519-1310
You’ll find detailed technical specifications, product attributes, condition classification, and real-time stock availability. All data is based on official records and meets industry standards for defense, aerospace, and industrial sourcing. Whether you’re performing a parts audit, validating compliance, or preparing a purchase order, this part listing supports accurate and efficient procurement.
"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."
0.750 inches maximum body width, 2.187 inches maximum body length, single pole type body style, 0.235 inches minimum and 0.250 inches maximum bushing length, 1.439 inches minimum and 1.501 inches maximum center to center distance between terminals parallel to length
Characteristics
Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.
- Body Style
- single pole type
- Bushing Length
- 0.235 inches minimum and 0.250 inches maximum
- Body Length
- 2.187 inches maximum
- Body Width
- 0.750 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 1.439 inches minimum and 1.501 inches maximum
- End Item Identification
- boeing b757 aircraft
- Mounting Surface To Terminal End Distance
- 2.234 inches nominal
- Pole Quantity
- 1
- Mounting Facility Type And Quantity
- 2 threaded hole
- Thread Quantity Per Inch
- 32
- Reset Method
- manual
- Nominal Thread Size
- 0.138 inches
- Unpackaged Unit Weight
- 0.250 pounds nominal
- Special Features
- 100 amp breaker; pull-out 8.0 pounds maximum to 2.0 pounds minimum; reset 12.0 pounds maximum to 2.0 pounds minimum; insulating barrier length 2.187 maximum by 0.062 inch thickness
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 2 tab w/screw
Related Parts & Specifications
This NSN includes a range of related parts designed for specific operational needs. Review each item below to find in-depth specifications, functional details, and guidance for correct application and replacement.
| Part Number | Name |
|---|---|
| 160-022-100 | Circuit Breaker |
| BACC18X100B | Circuit Breaker |
FAQs
Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for 160-022-100
What is the FSCG of the NSN 5925-01-519-1310?
Does the NSN 5925-01-519-1310 have a Schedule B code assigned?
Does NSN 5925-01-519-1310 require demilitarization?
Does NSN 5925-01-519-1310 contain precious materials?
Does NSN 5925-01-519-1310 contain hazardous materials?
When the NSN 5925-01-519-1310 was assigned to the Federal Catalog?
Need Consumables?
Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.
Recommended for You
Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.
Price & Availability
Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists:
Ready to Ship
This item is in stock and ready to ship. Available units may vary in condition (new, surplus, refurbished) and are stored across multiple verified facilities. Request a quote to confirm quantity and lead time.
| New Material | 23 |
| As Removed | 3 |
| New Surplus | 2 |
| Serviceable | 1 |
| Overhauled | 1 |
| Total | 30 |